What is G-MUC
One of the main features of G-MUC lies in the BMC compression molding under
high tem andHigh pressure. It entails the superior performance of heat-resistance,
impact-resistance anddimensional stability. Its stable quality helps mass-supply
from mass-production.Design modification of BMC formulation satisfies many
required performances suiting various applications.
1.Basic Performances.
1-1. Mechanical Strength.
| |
G-MUC |
Other Mfrs. |
| Item |
Test Method |
Unit |
Excely |
Forte |
'aBIS |
Acrylic K Corp |
MMA D Corp |
| Bending Strength |
JIS
K 6911 |
Mpa |
81.9 |
84.1 |
60.3 |
59.2 |
50.6 |
| Barcol Hardness |
JIS
K 6911 (934-1) |
|
64 |
62 |
62 |
54 |
64 |
| Impact Resistance |
*1 |
cm |
90 |
80 |
100 |
50 |
40 |
*1 Impact Resistance
Test Method Max.height where the test piece surface will not be broken or cracked
when 1Kg steel ball is fallen down. (Test piece size 200mm)
1-2. Heat Resistance.
| |
G-MUC |
Other Mfrs.
|
| Item |
Test Method |
Excely |
Forte |
'aBIS |
Acrylic K Corp |
MMA D Corp |
| Heat
Resistance |
*2
Oil Pan Test(JIS K 6902) |
523K No Change |
523K No Change |
523K No Change |
523K Whitened |
523K whitened |
| *3 Empty Pan Test |
No Change |
No Change |
No Change |
Whitened |
Whitened |
| Cigarette
Resistance |
*4
Cigarette Test |
No Change |
No Change |
No Change |
No Change |
No Change |
*2 Oil Pan Test(JIS K 6902)
Test Method To heat up an aluminum pan filled with 500ml oil and leave it on the
test piece for 20 minutes.
*3 Empty Pan Test
Test Method To examine how it changes 20 minutes after an empty pan heated up
to 623K is kept on the test piece.
*4 Cigarette Test
Test Method To examine the surface change after a cigarette is burnt on the test
piece. Judgement on changes follows JIS K 6902.
1-3.Dimensional Stability.
| |
G-MUC |
Other Mfrs. |
| Item |
Test Method |
Excely |
Forte |
'aBIS |
Acrylic K Corp |
MMA D Corp |
| Coefficient of Linear
Thermal Expansion |
*5
Coefficient ofLinear ThermalExpansion |
313K |
2.28x10-5
|
2.89x10-5
|
2.75x10-5
|
5.01x10-5
|
2.80x10-5
|
| 323K |
2.36x10-5
|
3.09x10-5
|
2.95x10-5
|
5.35x10-5
|
3.14x10-5
|
| 373K |
2.64x10-5
|
3.45x10-5
|
3.83x10-5
|
8.43x10-5
|
4.88x10-5
|
| 423K |
2.63x10-5
|
3.40x10-5
|
3.28x10-5
|
4.01x10-5
|
4.15x10-5
|
| 473K |
2.39x10-5
|
3.83x10-5
|
3.53x10-5
|
15.5x10-5
|
6.34x10-5
|
*5 Coefficient of Linear Thermal Expansion
Test Method To comply with JIS K 7197
TMA Compression Weight Loading Method
Temp. Increase Speed 5k/min
Loading Weight 2.0 gf19.6x10-3N
Atmosphere Nitrogen (200 ml/min)
1-4 UV Resistance
| |
G-MUC |
Other Mfrs. |
| Item |
Test Method |
Excely |
Forte |
'aBIS |
Acrylic K Corp |
MMA D Corp |
| UV Resistance |
*6 UV Resistance
|
No Change |
No Change |
No Change |
No Change |
No Change |
Comparison with other interior materials
| Item |
Test Method
|
G-MUC |
Polyester laminated |
PU Paint |
MMA D Corp |
| UV Resistance |
*6 UV Resistance |
0 Hr |
E=0 |
E=0 |
E=0 |
E=0 |
| 50 Hrs |
E=0.57 |
E=0.87 |
E=2.28 |
E=0.57 |
| 100 Hrs |
E=1.27 |
E=1.52 |
Unable of measuring |
E=0.58 |
| 150 Hrs |
E=1.55 |
E=2.29 |
E=0.90 |
| 200 Hrs |
E=1.98 |
E=2.48 |
E=1.39 |
*6 UV resistance
Test Method To comply with JIS K 6902
Test Device : STANDARD UV made by SUGA Testing Device Corp. LONGLIFE FADE METER
FAL-3
Test Period : 200 Hr
YOSHIMOTO TRADING CO.,LTD.
NO.2-7-26 MINAMISENBA, CHUO-KU, OSAKA 542-0081 JAPAN
TEL: +81-6-6264-6173 FAX: +81-6-6264-5531